Series 300 - Valve Seating Torques (In.-Lbs.)

Valve
Size

Standard Disc Differential Pressure
Undercut Diff. Press.
50 PSI
100 PSI
150 PSI
200 PSI
75 PSI
2"
100
106
111
117
-
2-1/2"
150
163
176
189
-
3"
207
220
232
244
-
4"
290
323
357
390
-
5"
423
481
540
598
-
6"
599
691
783
875
-
8"
1,060
1,183
1,307
1,430
819
10"
1,671
1,872
2,074
2,275
909
12"
2,568
2,795
3,023
3,250
1,445


All torques shown on the chart were derived from test data using water at 60°F. For torques using dry gases, multiply these numbers by 1.6. For torques involving other media, please consult the factory.

There is no safety factor included in the numbers shown on this chart. For actuator sizing, Center Line recommends that these values be multiplied by 1.2 for single valve applications, and 1.5 for 3-way ("tee") applications.

Under certain conditions, hydrodynamic torque can meet or exceed seating and unseating torques. When designing valve systems, hydrodynamic torque must be considered to help insure correct selection for the application.

 


 