Powell Valves - Pressure/Temperature Charts
Table
7 - ASTM A351 Grade CF3(a) & ASTM A351
Grade CF8(b)
(a) Not to be used over 800°F
(b) At temperatures over 1000°F, use only when the
carbon content is 0.04% or higher. This requirement must
be specified by customer when applicable.
Standard Class
|
Working
Pressures by Classes, psig
|
| Temperature,
°F |
150
|
300
|
400
|
600
|
900
|
1500
|
2500
|
4500
|
| -20
to 100 |
275
|
720
|
960
|
1440
|
2160
|
3600
|
6000
|
10,800
|
| 200 |
230
|
600
|
800
|
1200
|
1800
|
3000
|
5000
|
9000
|
| 300 |
205
|
540
|
720
|
1080
|
1620
|
2700
|
4500
|
8100
|
| 400 |
190
|
495
|
660
|
995
|
1490
|
2485
|
4140
|
7450
|
| 500 |
170
|
465
|
620
|
930
|
1395
|
2330
|
3880
|
6985
|
| 600 |
140
|
435
|
580
|
875
|
1310
|
2185
|
3640
|
6550
|
| 650 |
125
|
430
|
575
|
860
|
1290
|
2150
|
3580
|
6445
|
| 700 |
110
|
425
|
565
|
850
|
1275
|
2125
|
3540
|
6370
|
| 750 |
95
|
415
|
555
|
830
|
1245
|
2075
|
3460
|
6230
|
| 800 |
80
|
405
|
540
|
805
|
1210
|
2015
|
3360
|
6050
|
| 850 |
65
|
395
|
530
|
790
|
1190
|
1980
|
3300
|
5940
|
| 900 |
50
|
390
|
520
|
780
|
1165
|
1945
|
3240
|
5830
|
| 950 |
35
|
380
|
510
|
765
|
1145
|
1910
|
3180
|
5725
|
| 1000 |
20
|
320
|
430
|
640
|
965
|
1605
|
2675
|
4815
|
| 1050 |
20(1)
|
310
|
410
|
615
|
925
|
1545
|
2570
|
4630
|
| 1100 |
20(1)
|
255
|
345
|
515
|
770
|
1285
|
2145
|
3855
|
| 1150 |
20(1)
|
200
|
265
|
400
|
595
|
995
|
1655
|
2985
|
| 1200 |
20(1)
|
155
|
205
|
310
|
465
|
770
|
1285
|
2315
|
| 1250 |
20(1)
|
115
|
150
|
225
|
340
|
565
|
945
|
1695
|
| 1300 |
20(1)
|
85
|
115
|
170
|
255
|
430
|
715
|
1285
|
| 1350 |
20(1)
|
60
|
80
|
125
|
185
|
310
|
515
|
925
|
| 1400 |
20(1)
|
50
|
65
|
95
|
145
|
240
|
400
|
720
|
| 1450 |
15(1)
|
35
|
45
|
70
|
105
|
170
|
285
|
515
|
| 1500 |
10(1)
|
25
|
35
|
55
|
80
|
135
|
230
|
410
|
NOTE: (1) For welding end valves only. Flanged end ratings
terminate at 1000°F
Special Class
|
Working
Pressures by Classes, psig
|
| Temperature,
°F |
150
|
300
|
400
|
600
|
900
|
1500
|
2500
|
4500
|
| -20
to 100 |
290
|
750
|
1000
|
1500
|
2250
|
3750
|
6250
|
11,250
|
| 200 |
255
|
670
|
890
|
1335
|
2005
|
3345
|
5570
|
10,030
|
| 300 |
230
|
600
|
800
|
1200
|
1800
|
3000
|
5000
|
9000
|
| 400 |
210
|
555
|
735
|
1105
|
1660
|
2765
|
4605
|
8295
|
| 500 |
200
|
520
|
690
|
1035
|
1555
|
2595
|
4320
|
7780
|
| 600 |
185
|
490
|
650
|
975
|
1465
|
2440
|
4065
|
7315
|
| 650 |
185
|
480
|
640
|
960
|
1440
|
2395
|
3995
|
7190
|
| 700 |
180
|
470
|
630
|
945
|
1415
|
2355
|
3930
|
7070
|
| 750 |
175
|
465
|
615
|
925
|
1390
|
2315
|
3855
|
6945
|
| 800 |
175
|
450
|
600
|
900
|
1350
|
2250
|
3750
|
6750
|
| 850 |
170
|
440
|
580
|
885
|
1325
|
2205
|
3680
|
6620
|
| 900 |
165
|
435
|
575
|
865
|
1300
|
2165
|
3605
|
6495
|
| 950 |
165
|
425
|
565
|
850
|
1275
|
2120
|
3535
|
6365
|
| 1000 |
155
|
405
|
545
|
815
|
1220
|
2035
|
3395
|
6105
|
| 1050 |
150
|
385
|
515
|
770
|
1155
|
1930
|
3215
|
5785
|
| 1100 |
125
|
320
|
430
|
645
|
965
|
1605
|
2680
|
4820
|
| 1150 |
95
|
250
|
330
|
495
|
745
|
1245
|
2070
|
3730
|
| 1200 |
75
|
195
|
255
|
385
|
580
|
965
|
1605
|
2895
|
| 1250 |
55
|
140
|
190
|
285
|
425
|
705
|
1180
|
2120
|
| 1300 |
40
|
105
|
145
|
215
|
320
|
535
|
895
|
1605
|
| 1350 |
30
|
75
|
105
|
155
|
260
|
385
|
645
|
1155
|
| 1400 |
25
|
60
|
80
|
120
|
180
|
300
|
500
|
900
|
| 1450 |
15
|
45
|
55
|
85
|
130
|
215
|
355
|
645
|
| 1500 |
15
|
35
|
45
|
70
|
105
|
170
|
285
|
515
|
NOTE: Special Class Ratings apply to Threaded and Weld
End Valves only and require upgrading per paragraph 8
of ASME B16.34
|
|
Toll
Free: 1-800-447-4230
Fax: 713-462-4187
Local: (713) 462-4181
24 Hr. Pager (713) 764-2285
E-mail: valves@aivinc.com
Copyright© AIV, Inc. 2001
|