Powell Valves - Pressure/Temperature Charts
Table
5 - ASTM A217 Grade C12
Use normalized and tempered material only.
Standard Class
|
Working
Pressures by Classes, psig
|
| Temperature,
°F |
150
|
300
|
400
|
600
|
900
|
1500
|
2500
|
4500
|
| -20
to 100 |
290
|
750
|
1000
|
1500
|
2250
|
3750
|
6250
|
11,250
|
| 200 |
260
|
750
|
1000
|
1500
|
2250
|
3750
|
6250
|
11,250
|
| 300 |
230
|
730
|
970
|
1455
|
2185
|
3640
|
6070
|
10,925
|
| 400 |
200
|
705
|
940
|
1410
|
2115
|
3530
|
5880
|
10,585
|
| 500 |
170
|
665
|
885
|
1330
|
1995
|
3325
|
5540
|
9965
|
| 600 |
140
|
605
|
805
|
1210
|
1815
|
3025
|
5040
|
9070
|
| 650 |
125
|
590
|
785
|
1175
|
1765
|
2940
|
4905
|
8825
|
| 700 |
110
|
570
|
755
|
1135
|
1705
|
2840
|
4730
|
8515
|
| 750 |
95
|
530
|
710
|
1065
|
1595
|
2660
|
4430
|
7970
|
| 800 |
80
|
510
|
675
|
1015
|
1525
|
2540
|
4230
|
7610
|
| 850 |
65
|
485
|
650
|
975
|
1460
|
2435
|
4060
|
7305
|
| 900 |
50
|
450
|
600
|
900
|
1350
|
2245
|
3745
|
6740
|
| 950 |
35
|
375
|
505
|
755
|
1130
|
1885
|
3145
|
5655
|
| 1000 |
20
|
255
|
340
|
505
|
760
|
1270
|
2115
|
3805
|
| 1050 |
20(1)
|
170
|
230
|
345
|
515
|
855
|
1430
|
2570
|
| 1100 |
20(1)
|
115
|
150
|
225
|
340
|
565
|
945
|
1695
|
| 1150 |
20(1)
|
75
|
100
|
150
|
225
|
375
|
630
|
1130
|
| 1200 |
20(1)
|
50
|
70
|
105
|
155
|
255
|
430
|
770
|
NOTE: (1) For welding end valves only. Flanged end ratings
terminate at 1000°F
Special Class
|
Working
Pressures by Classes, psig
|
| Temperature,
°F |
150 |
300 |
400 |
600 |
900 |
1500 |
2500 |
4500 |
| -20
to 100 |
290
|
750
|
1000
|
1500
|
2250
|
3750
|
6250
|
11,250
|
| 200 |
290
|
750
|
1000
|
1500
|
2250
|
3750
|
6250
|
11,250
|
| 300 |
290
|
750
|
1000
|
1500
|
2250
|
3750
|
6250
|
11,250
|
| 400 |
290
|
750
|
1000
|
1500
|
2250
|
3750
|
6250
|
11,250
|
| 500 |
290
|
750
|
1000
|
1500
|
2250
|
3750
|
6250
|
11,250
|
| 600 |
290
|
750
|
1000
|
1500
|
2250
|
3750
|
6250
|
11,250
|
| 650 |
290
|
750
|
1000
|
1500
|
2250
|
3750
|
6250
|
11,250
|
| 700 |
280
|
735
|
980
|
1465
|
2200
|
3665
|
6110
|
10,995
|
| 750 |
280
|
730
|
970
|
1460
|
2185
|
3645
|
6070
|
10,930
|
| 800 |
275
|
720
|
960
|
1440
|
2160
|
3600
|
6000
|
10,800
|
| 850 |
260
|
680
|
905
|
1355
|
2030
|
3385
|
5645
|
10,160
|
| 900 |
230
|
600
|
800
|
1200
|
1800
|
3000
|
5000
|
9000
|
| 950 |
180
|
470
|
630
|
945
|
1415
|
2355
|
3930
|
7070
|
| 1000 |
120
|
315
|
425
|
635
|
950
|
1585
|
2645
|
4755
|
| 1050 |
80
|
215
|
285
|
430
|
645
|
1070
|
1785
|
3215
|
| 1100 |
55
|
140
|
190
|
285
|
425
|
710
|
1180
|
2120
|
| 1150 |
35
|
95
|
125
|
190
|
285
|
470
|
785
|
1415
|
| 1200 |
25
|
65
|
85
|
130
|
195
|
320
|
535
|
965
|
NOTE: Special Class Ratings apply to Threaded and Weld
End Valves only and require upgrading per paragraph 8
of ASME B16.34
|
|
Toll
Free: 1-800-447-4230
Fax: 713-462-4187
Local: (713) 462-4181
24 Hr. Pager (713) 764-2285
E-mail: valves@aivinc.com
Copyright© AIV, Inc. 2001
|