Powell Valves - Pressure/Temperature Charts
Table
1 - ASTM A216 Grade WBC
Upon
prolonged exposure to temperatures above 800°F, the
carbide phase of steel may be converted to graphite.
Permissable, but not recommended for prolonged use above
800°F.
Standard Class
|
Working
Pressures by Classes, psig
|
| Temperature,
°F |
150
|
300
|
400
|
600
|
900
|
1500
|
2500
|
4500
|
| -20
to 100 |
285
|
740
|
990
|
1480
|
2220
|
3705
|
6170
|
11,110
|
| 200 |
260
|
675
|
900
|
1350
|
2025
|
3375
|
5625
|
10,120
|
| 300 |
230
|
655
|
875
|
1315
|
1970
|
3280
|
5470
|
9845
|
| 400 |
200
|
635
|
845
|
1270
|
1900
|
3170
|
5280
|
9505
|
| 500 |
170
|
300
|
800
|
1200
|
1795
|
2995
|
4990
|
8980
|
| 600 |
140
|
550
|
730
|
1095
|
1640
|
2735
|
4560
|
8210
|
| 650 |
125
|
535
|
715
|
1075
|
1610
|
2685
|
4475
|
8055
|
| 700 |
110
|
535
|
710
|
1065
|
1600
|
2665
|
4440
|
7990
|
| 750 |
95
|
505
|
670
|
1010
|
1510
|
2520
|
4200
|
7560
|
| 800 |
80
|
410
|
550
|
825
|
1235
|
2060
|
3430
|
6170
|
Special Class
|
Working
Pressures by Classes, psig
|
| Temperature,
°F |
150
|
300
|
400
|
6001500
|
900
|
1500
|
2500
|
4500
|
| -20
to 100 |
290
|
750
|
1000
|
1500
|
2250
|
3750
|
6250
|
11250
|
| 200 |
290
|
750
|
1000
|
1500
|
2250
|
3750
|
6250
|
11250
|
| 300 |
290
|
750
|
1000
|
1500
|
2250
|
3750
|
6250
|
11250
|
| 400 |
290
|
750
|
1000
|
1500
|
2250
|
3750
|
6250
|
11250
|
| 500 |
290
|
750
|
1000
|
1500
|
2250
|
3750
|
6250
|
11250
|
| 600 |
275
|
715
|
950
|
1425
|
2140
|
3565
|
5940
|
10690
|
| 650 |
270
|
700
|
935
|
1400
|
2100
|
3495
|
5825
|
10485
|
| 700 |
265
|
695
|
925
|
1390
|
2080
|
3470
|
5780
|
10405
|
| 750 |
240
|
630
|
840
|
1260
|
1890
|
3150
|
5250
|
9450
|
| 800 |
200
|
515
|
685
|
1030
|
1545
|
2570
|
4285
|
7715
|
NOTE: Special Class Ratings apply to Threaded and Weld
End Valves only and require upgrading per paragraph 8
of ASME B16.34
|
|