Dresser/Cooper
Valves - Pressure
- Temperature Charts
Pressure - Temperature Ratings for Stainless Steel Flanged
Fittings & Valves
CF8 (304SS)
|
Maximum
Service Temperature
(°F)
|
Maximum
Working Pressure (PSIG) for CF8 (304 SS)
|
|
ANSI
CL 150
|
ANSI
CL 300
|
ANSI
CL 600
|
ANSI
CL 900
|
ANSI
CL 1500
|
ANSI
CL 2500
|
|
-20
to 1 00
|
275
|
720
|
1440
|
2160
|
3600
|
6000
|
|
200
|
235
|
600
|
1200
|
1800
|
3000
|
5000
|
|
300
|
205
|
530
|
1055
|
1585
|
2640
|
4400
|
|
400
|
180
|
470
|
940
|
1410
|
2350
|
3920
|
|
500
|
170
|
435
|
875
|
1310
|
2185
|
3640
|
|
600
|
140
|
415
|
830
|
1245
|
2075
|
3460
|
|
650
|
125
|
410
|
815
|
1225
|
2040
|
3400
|
|
700
|
110
|
405
|
805
|
1210
|
2015
|
3360
|
|
750
|
95
|
400
|
795
|
1195
|
1990
|
3320
|
|
800
|
80
|
395
|
790
|
1180
|
1970
|
3280
|
|
850
|
65
|
390
|
780
|
1165
|
1945
|
3240
|
|
900
|
50
|
385
|
770
|
1150
|
1920
|
3200
|
|
950
|
35
|
375
|
750
|
1125
|
1870
|
3120
|
|
1000
|
20
|
325
|
645
|
965
|
1610
|
2685
|
|
1050
|
*
|
310
|
620
|
925
|
1545
|
2570
|
|
1100
|
*
|
260
|
515
|
770
|
1285
|
2145
|
|
1150
|
*
|
195
|
390
|
585
|
980
|
1630
|
|
1200
|
*
|
155
|
310
|
465
|
770
|
1285
|
|
1250
|
*
|
110
|
220
|
330
|
550
|
915
|
|
1300
|
*
|
85
|
165
|
245
|
410
|
685
|
|
1350
|
*
|
60
|
125
|
185
|
310
|
515
|
|
1400
|
*
|
50
|
95
|
145
|
240
|
400
|
|
1450
|
*
|
35
|
70
|
105
|
170
|
285
|
|
1500
|
*
|
25
|
50
|
70
|
120
|
200
|
*Note: Not recommended for service over
10000 °F
|
Hydrostatic
Shell Test Pressure
|
|
425
|
1100
|
2175
|
3250
|
5400
|
9000
|
Pressure
- Temperature Ratings for Stainless Steel Flanged Fittings
& Valves
CF8M (316SS)
|
Maximum
Service
Temperature
(°F)
|
Maximum
Working Pressure (PSIG) for CF8M (316 SS)
|
|
ANSI
CL 150
|
ANSI
CL 300
|
ANSI
CL 600
|
ANSI
CL 900
|
ANSI
CL 1500
|
ANSI
CL 2500
|
|
-20
to 100
|
275
|
720
|
1440
|
2160
|
3600
|
6000
|
|
200
|
240
|
620
|
1240
|
1860
|
3095
|
5160
|
|
300
|
215
|
560
|
1120
|
1680
|
2795
|
4660
|
|
400
|
195
|
515
|
1030
|
1540
|
2570
|
4280
|
|
500
|
170
|
480
|
955
|
1435
|
2390
|
3980
|
|
600
|
140
|
450
|
905
|
1355
|
2255
|
3760
|
|
650
|
125
|
445
|
890
|
1330
|
2220
|
3700
|
|
700
|
110
|
430
|
865
|
1295
|
2160
|
3600
|
|
750
|
95
|
425
|
845
|
1270
|
2110
|
3520
|
|
800
|
80
|
415
|
830
|
1245
|
2075
|
3460
|
|
850
|
65
|
405
|
810
|
1215
|
2030
|
3320
|
|
900
|
50
|
395
|
790
|
1180
|
1970
|
3280
|
|
950
|
35
|
385
|
775
|
1160
|
1930
|
3220
|
|
1000
|
20
|
365
|
725
|
1090
|
1820
|
3030
|
|
1050
|
*
|
360
|
720
|
1080
|
1800
|
3000
|
|
1100
|
*
|
325
|
645
|
965
|
1610
|
2685
|
|
1150
|
*
|
275
|
550
|
825
|
1370
|
2285
|
|
1200
|
*
|
205
|
410
|
620
|
1030
|
1715
|
|
1250
|
*
|
180
|
365
|
545
|
910
|
1515
|
|
1300
|
*
|
140
|
275
|
410
|
685
|
1145
|
|
1350
|
*
|
105
|
205
|
310
|
515
|
860
|
|
1400
|
*
|
75
|
150
|
225
|
380
|
630
|
|
1450
|
*
|
60
|
115
|
175
|
290
|
485
|
|
1500
|
*
|
40
|
85
|
125
|
205
|
345
|
*Note:
Not recommended for service over 10000 °F
|
Hydrostatic
Shell Test Pressure
|
|
425
|
1100
|
2175
|
3250
|
5400
|
9000
|
Notes:
1.
These ratings are in accordance with ANSI B16.341977.
2.
Pressure -Temperature ratings apply to design only and
do not imply that standard gasket and packing materials
are suitable for the complete range or temperature.
3.
Primary service pressure ratings are those shown in bold
face type.
|