Dresser/Cooper Valves - Pressure - Temperature Charts


Pressure - Temperature Ratings for Stainless Steel Flanged Fittings & Valves
CF8 (304SS)

Maximum Service Temperature
(°F)
Maximum Working Pressure (PSIG) for CF8 (304 SS)
ANSI
CL 150
ANSI
CL 300
ANSI
CL 600
ANSI
CL 900
ANSI
CL 1500
ANSI
CL 2500
-20 to 1 00
275
720
1440
2160
3600
6000
200
235
600
1200
1800
3000
5000
300
205
530
1055
1585
2640
4400
400
180
470
940
1410
2350
3920
500
170
435
875
1310
2185
3640
600
140
415
830
1245
2075
3460
650
125
410
815
1225
2040
3400
700
110
405
805
1210
2015
3360
750
95
400
795
1195
1990
3320
800
80
395
790
1180
1970
3280
850
65
390
780
1165
1945
3240
900
50
385
770
1150
1920
3200
950
35
375
750
1125
1870
3120
1000
20
325
645
965
1610
2685
1050
*
310
620
925
1545
2570
1100
*
260
515
770
1285
2145
1150
*
195
390
585
980
1630
1200
*
155
310
465
770
1285
1250
*
110
220
330
550
915
1300
*
85
165
245
410
685
1350
*
60
125
185
310
515
1400
*
50
95
145
240
400
1450
*
35
70
105
170
285
1500
*
25
50
70
120
200

*Note: Not recommended for service over 10000 °F

 

Hydrostatic Shell Test Pressure
425
1100
2175
3250
5400
9000

 

 

Pressure - Temperature Ratings for Stainless Steel Flanged Fittings & Valves
CF8M (316SS)

Maximum
Service
Temperature
(°F)
Maximum Working Pressure (PSIG) for CF8M (316 SS)
ANSI
CL 150
ANSI
CL 300

ANSI
CL 600

ANSI
CL 900
ANSI
CL 1500
ANSI
CL 2500
-20 to 100
275
720
1440
2160
3600
6000
200
240
620
1240
1860
3095
5160
300
215
560
1120
1680
2795
4660
400
195
515
1030
1540
2570
4280
500
170
480
955
1435
2390
3980
600
140
450
905
1355
2255
3760
650
125
445
890
1330
2220
3700
700
110
430
865
1295
2160
3600
750
95
425
845
1270
2110
3520
800
80
415
830
1245
2075
3460
850
65
405
810
1215
2030
3320
900
50
395
790
1180
1970
3280
950
35
385
775
1160
1930
3220
1000
20
365
725
1090
1820
3030
1050
*
360
720
1080
1800
3000
1100
*
325
645
965
1610
2685
1150
*
275
550
825
1370
2285
1200
*
205
410
620
1030
1715
1250
*
180
365
545
910
1515
1300
*
140
275
410
685
1145
1350
*
105
205
310
515
860
1400
*
75
150
225
380
630
1450
*
60
115
175
290
485
1500
*
40
85
125
205
345

*Note: Not recommended for service over 10000 °F

 

Hydrostatic Shell Test Pressure
425
1100
2175
3250
5400
9000

Notes:

1. These ratings are in accordance with ANSI B16.341977.